Nu-Gen Online UPS Systems Single Phase

Nu-Gen Online Single Phase UPS is a Double Conversion UPS with Output PF@0.9 to cater large systems within Compact design.Its designed with Microprocessor to ensure CVCF even at very poor power contions and fluctuations sites.

Nu-Gen Online UPS Systems are very much suitable for Work Stations/ATM,s/Hospital/SOHO segment/

  • True Online, Double Conversion, PWM Technology.
  • Fully Digitized Microprocessor Control, High Frequency, Pure Sine Wave Output.
  •  CVCF (Constant Voltage Constant Frequency)
  • LCD Display and Wide Input Voltage Range
  • High Input Power Factor >0.99
  • Static Bypass and Cold Start
  • IGBT Based - Inverter & Rectifier
  • Isolation Transformer Compatible
  •  Advanced Battery Management
  •  Automatic Battery Charge in UPS Off Mode
  •  EMI/RFI and Noise Filter
  •  Generator and Solar Compatible
  • High Reliability Digital Control
  • Auto-start Function
  •  ECO Mode

Model

Capacity
NG1101L3 NG1102L4 NG1102L6 NG1102L8 NG1103L6 NG1103L8 NG1105L16 NG1106L16 NG1110L16
1 kVA 2 kVA 3 kVA 5 kVA 6 kVA 10 kVA
Input:
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 110V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
Output
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) <2% (Linear load), <5% (Non Liner Load)
Crest Factor 3:01
Efficiency Up to 94% Dual Conversion Mode, 99% ECO Mode
Battery
DC Voltage 36V, 48V, 72V, 96V, 72V, 96V, 192-220V Configurable
Charge Current 6.5 A Configurable
Typical Recharge Time 8 Hours (90% of full capacity)
System Features
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
Environmental
Temperature Operating: 0~45°C, Storage: -10ºC ~ 55ºC
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Low Audible Noise Level
Physical
Dimension WxDxH (mm) 144x400x215, 192x469x399, 220x481x438,
Weight (Kg) 5.6, 10.7, 10.8, 11.2, 10.8, 11.2, 17, 18, 20
Standards
Quality ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE